Avaliação in vivo da temperatura pulpar de pré-molares humanos submetidos à luz Led Polywave® em diferentes protocolos e cenários clínicos
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Estadual de Ponta Grossa
Abstract
Objective: To evaluate the pulp temperature (PT) of premolars in real time and pulp
temperature increase (ΔT) induced by a light-emitting diode (LED) light curing unit
(LCU) in class V preparations, under simultaneous airflow; and during restorative
procedure with conventional and bulk fill composite resins. Material and methods:
Aproved by local Ethics Committee (protocol #1,954,754 and #255.945), premolars of
26 patients who required extraction for orthodontic reasons were anesthetized and
received absolute isolation. An occlusal access was performed with refrigerated highspeed
handpiece, and the pulp was slightly exposed. A sterile thermocouple probe was
then introduced into the pulp chamber (Temperature Data Acquisition - Thermes WFI,
Physitemp). The tooth received a class V preparation, and 3 tests were performed
according to the experimental groups. (1) exposition to a light of a polywave LED LCU
(Bluephase 20i, Ivoclar Vivadent) with one of the following exposure modes(EM): 10 s
at Low power (10s/L); 10 s at High power (10s/H); 30 s at High power (30s/H); 60 s at
High power (60s/H); and 5 s in Turbo mode (5s/T). (2) continuous airflow
simultaneously at 30 s/H exposure, compared to the control no-air. (3) PT data were
collected during the class V restorations with: Tetric N Ceram Bulkfill (Ivoclar Vivadent)
single photoactivated for 10 s (High mode, Bluephase 20i, Ivoclar Vivadent); Filtek
Z250 in two increments (3M ESPE) photoactivated for 10 s each; Filtek Z350 (3M
ESPE) single photoactivated for 40 s. PT was recorded every 0.2 s and the values
were submitted to statistical analysis one-way (ANOVA) and Bonferroni Post-test (α =
0.05); paired Student t-test (α = 0.05); and Tukey's test (α = 0.05), respectively. The
linear correlation between radiant exposure and PT was established by linear
regression analysis. Results: All the EMs tested in the first stage generated an
increase in PT (p <0.001). The exposure of 60 s/H generated ΔT of 5.5oC (p <0.001).
A positive correlation was observed between radiant exposure and ΔT (r2=0.8962,
p<0.001). For the exposures of 30 s/H, both the peak of PT and ΔT were significantly
higher for the group without the airflow than with airflow and baseline PT (p <0.001),
and the group with airflow had PT values significantly lower than baseline PT values
(p = 0.003). For the restorations, only the photoactivation of the Z350 for 40 s (40.2 +
1.7°C) promoted a higher PT increase than baseline (35.0 ± 0.8°C) (p <0.001). PT after
photoactivation of bulk fill CR was lower than that observed in other techniques (p =
0.012). Conclusion: Exposures with polywave® LEDs increased PT in most cases
below 5.5°C, however the exposures of 60 s presented a risk to pulp vitality. The airflow
was able to prevent PT increases, and additionally caused a decrease of the PT after
the exposure. For the light cured restorations, the drop in PT during cavity preparation
prevented a drastic PT increase during restorative procedures, demonstrating that the
radiant exposure added to the exotherm of the materials were not sufficient to elevate
PT to harmful levels.
Description
Citation
ZARPELLON DC. Avaliação in vivo da temperatura pulpar de pré-molares humanos submetidos à luz LED Polywave® em diferentes protocolos e cenários clínicos. [Tese] Doutorado em Clínica Integrada. Ponta Grossa: Universidade Estadual de Ponta Grossa; 2019.
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwised noted, this item's license is described as Acesso Aberto