Tratamento de Efluente de Microcervejaria por Coagulação e Filtração Rápida
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Estadual de Ponta Grossa
Abstract
Breweries produce a large amount of effluents with a high organic matter load that, if not treated
properly, can contaminate the environment. This study investigated the simultaneous
coagulation and rapid filtration processes in the treatment of microbrewery effluents, evaluating
a Double Filtration (DF) and Triple Filtration (TF) pilot unit for the post-treatment of anaerobic
decant digester effluents. To monitor the treatment stages, analyses were performed on
Apparent Color, True Color, Biochemical Oxygen Demand (BOD5), Chemical Oxygen
Demand (COD), Total Phenols, Total Phosphorus (PT), Ammoniacal Nitrogen (N-NH3),
Nitrate (NO3
-
), Nitrite (NO2
-
), Total Kjeldahl Nitrogen (NTK), Total Dissolved Solids (TDS),
TDS - fixed, TDS - volatile, Total Suspended Solids (TSS), TDS - fixed, TDS - volatile, Total
Solids (TS), TDS - fixed, TDS - volatile and Turbidity. To determine the best dosages of Ferric
Chloride (FeCl3), Polyaluminum Chloride (PAC) and Tannins (TAN) coagulants in relation to
turbidity and color removal, coagulation diagrams were constructed in Jar Test, varying the
concentrations from 50 mg L-1
to 400 mg L-1
at different pH values from 4.5 to 8.0. After
obtaining the best coagulation conditions, rapid filtration studies were carried out at a rate of
120 m3
.m2
.day-1
using double filtration (DF) with gravel and sand and triple filtration (TF) with
gravel, sand, coal and zeolite. The treatment tests in the filters were carried out with sample
collection at intervals of 30, 60 and 90 minutes to measure their efficiency and verify whether
they maintained the removal capacity of the physicochemical parameters throughout the
coagulation/filtration process. Studies of iodine number in activated carbon and cation
exchange capacity (CEC) were carried out to estimate the loss of efficiency of these filters in
relation to the filtered volume. The tests showed that the best results were obtained at pH close
to 7.0 for the three coagulants. It was found that for the passage of microbrewery effluents in
the DF and TF system, it was necessary to correct the coagulant concentrations due to
oscillations in the color and turbidity parameters, thus the concentrations of 130 mg L-1
of
FeCl3, 95 mg L-1
of PAC and 100 mg L-1 TAN were necessary. After 30 minutes of coagulation
and filtration, the results indicated significant reductions in the analyzed parameters. For FeCl3,
PAC and TAN, the apparent color decreased between 89% and 92%, while the turbidity ranged
from 92% to 93%. Total dissolved solids (TDS) were reduced between 84% and 86%, total
suspended solids (TSS) between 78% and 87%, and total solids (TS) between 83% and 88%.
BOD and COD parameters showed reductions of 25% to 31%, while ammonium compounds
(N-NH3) and total nitrogen (NTK) had reductions between 47% to 49% and 52%, respectively.
Total phosphorus (TP) showed a reduction of 64% to 68%, and total phenols, from 77% to 78%.
With coagulation followed by double or triple filtration, the results were even more expressive.
The apparent color was reduced by up to 97%, TDS and TSS reached reductions of 94%, while
ST reached 95%. Turbidity decreased by up to 98%, and BOD5 and COD reductions exceeded
55% and 64%, respectively. N-NH3 and NTK showed reductions of up to 69% and 74%, while
phosphorus and phenols reached values of 99% and 100%. Regarding the use of coal and zeolite
in the TF, it was found that after the treatment of 1,500 L, there was a reduction of 5.38% in
the adsorption capacity of activated carbon and of 2.95% in the cation exchange capacity of
clinoptilolite. Regarding the performance of the coagulants in the removal of the physical-
chemical parameters, it was observed that PAC and tannins presented similar results in the Jar
Test tests (construction of the coagulation diagrams), however, in the coagulation stage
followed by DF and TF, the TAN coagulant obtained, in general, the best performance,
achieving the best results. For the removal of all the parameters studied, the proposed system
was highly efficient, meeting the disposal criteria of the current legislation, with the exception
of BOD and COD. It is concluded that the use of coagulation followed by rapid filtration can
be a promising technique in the post-treatment of brewery effluents, provided that a more
efficient pre-treatment is carried out.
Description
Citation
PUPIN, Amanda Vedam. Tratamento de efluente de microcervejaria por coagulação e filtração
rápida. 2024. Dissertação (Mestrado em Química) - Universidade Estadual de Ponta Grossa, Ponta Grossa, 2024.
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwised noted, this item's license is described as Acesso Aberto