Análise in vitro da resistência fluxural de uma resina composta direta e uma resina laboratorial de segunda geração associadas ou não a fibras de reforço
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
UNIVERSIDADE ESTADUAL DE PONTA GROSSA
Abstract
The present study aims to evaluate in vitro the flexural strength of the direct
composite resin (FiltekTM Z-250 – 3M/ESPE) and of the second generation
laboratory resin (CeseaDST II – Kuraray) either associated or not to glass fibers
(Fibrex-coronal – Angelus), varying the source of photoactivating (L.E.Demetron 1
– Kerr e Strobolux – EDG). Fifty-six samples were made inside a biparted metalic
matrix, 13.0 mm in diameter X 2.4 mm thick, divided into 8 study groups (n=7): GI
– Resin FiltekTM Z-250/ Fibreless/ LED; GII – Resin FiltekTM Z-250/ Fibreless/
Strobolux; GIII - Resin FiltekTM Z-250/ Fibrex-coronal/ LED; GIV - Resin FiltekTM
Z-250/ Fibrex-coronal/ Strobolux; GV – Resin CeseaDST II/ Fibreless / LED; GVI -
Resin CeseaDST II/ Fibreless / Strobolux; GVII - Resin CeseaDST II/ Fibrexcoronal/
LED; GVIII - Resin CeseaDST II/ Fibrex-coronal/ Strobolux. The samples
were under the test of biaxial flexural strength in the Kratos equipment, with
speed of 1 ± 0.5 mm/min and load cell of 500 Kgf. The flexural strength values
were submitted to the Tukey test (P=0,01). The rate of the results in MPa were:
GI – 187.91 ± 32.78; GII – 196.76 ± 31.15; GIII – 208.27 ± 18.79; GIV – 218.02 ±
15.76; GV – 101.72 ± 11.25; GVI – 103.05 ± 9.56; GVII – 164.76 ± 12.54 e GVIII
– 176.75 ± 47.03. The conclusion is that the analyzed composites showed
different behaviors in vitro; the direct composite FiltekTM Z-250 showed higher
values of flexural strength in all the studied groups; the type of light source did not
interfere in the flexural strength of the evaluated composites; reinforcement with
fibers increased the flexural strength both evaluated composites, however only for
the indirect composite CeseaDST II that increase was significant.
Description
Citation
PORTERO, Priscila Paiva. Análise in vitro da resistência fluxural de uma resina composta direta e uma resina laboratorial de segunda geração associadas ou não a fibras de reforço. 2006. 125 f. Dissertação (Mestrado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2006.