Avaliação do eco-Doppler na predição da necessidade de arteriografia do território aorto-ilíaco em pacientes submetidos a revascularização arterial infra-inguinal

DSpace/Manakin Repository

Avaliação do eco-Doppler na predição da necessidade de arteriografia do território aorto-ilíaco em pacientes submetidos a revascularização arterial infra-inguinal

Show simple item record

dc.contributor.author Jacobovicz, Cláudio
dc.contributor.author Timi, Jorge R. Ribas
dc.contributor.author França, Luís Henrique Gil
dc.contributor.author Stahlke Júnior, Henrique Jorge
dc.contributor.author Nakahara, Judy
dc.date.accessioned 2012-08-20T15:26:39Z
dc.date.available 2012-08-20T15:26:39Z
dc.date.issued 2004
dc.identifier.citation JACOBOVICZ, C. et al. Avaliação do eco-Doppler na predição da necessidade de arteriografia do território aorto-ilíaco em pacientes submetidos a revascularização arterial infra-inguinal. J vasc br, Porto Alegre, v.3, n.1, p. 5-12, 2004 pt_BR
dc.identifier.issn 1677-5449
dc.identifier.uri http://ri.uepg.br:8080/riuepg//handle/123456789/786
dc.description.abstract Objetivo: Determinar se a ultra-sonografia Doppler pode afastar lesões hemodinamicamente significativas no território aorto-ilíaco em pacientes com pulso femoral palpável, limitando o exame arteriográfico seletivamente ao membro inferior sintomático. Método: Foram estudados 82 pacientes submetidos a revascularização arterial infra-inguinal no Serviço de Cirurgia Vascular do Hospital de Clínicas da UFPR entre janeiro de 1999 e dezembro de 2000. Todos apresentavam pulsos arteriais em região femoral normalmente palpável no membro isquêmico e, em pré-operatório, realizaram exame ultra-sonográfico para afastar lesões hemodinamicamente significativas em território aorto-ilíaco, posteriormente comparado com a arteriografia. Resultados: Os exames foram concordantes em 80 destes pacientes e inconclusivos em dois. Com isso, a especificidade foi de 97,56%, e o valor preditivo negativo, de 100%. A observação mais importante foi a acurácia do eco-Doppler para afastar lesões significativas em território aorto-ilíaco (97,56%) quando comparado com o exame padrão-ouro. Conclusão: Pacientes submetidos a revascularização arterial infrainguinal e que apresentam pulso arterial femoral normalmente palpável podem ser submetidos à cirurgia apenas com o eco-Doppler para afastar lesões hemodinamicamente significativas em território aortoilíaco. Assim, o exame arteriográfico seria utilizado apenas seletivamente no membro isquêmico, propiciando uma avaliação mais rápida e com menor quantidade de contraste. pt_BR
dc.description.abstract Objective: To determine if Doppler ultrasonography could rule out any hemodynamically significant aortoiliac lesion in patients with palpable femoral pulse, thus leading to selective arteriography of the symptomatic lower extremity. Method: Preoperative evaluation was performed in eighty-two patients who underwent infrainguinal arterial reconstruction in the Division of Vascular Surgery of Universidade Federal do Paraná, Brazil from January 1999 to December 2000. All patients had preoperative normal femoral pulse in the symptomatic extremity and underwent ultrasonography of the aortoiliac segment to rule out any hemodynamically significant lesion of this segment. The ultrasonography was later compared with the arteriography, considered the gold standard. Results: For eighty patients, there was agreement between both studies (ultrasonography and arteriography), and for only two, the ultrasonography was inconclusive. Thus, the specificity of the Doppler ultrasonography was 97.56% and the negative predictive value was 100%. The most important result was the accuracy (97.56%) of the ultrasonography to rule out significant lesions of the aortoiliac segment, when compared with the arteriography. Conclusion: Infrainguinal arterial reconstruction can be performed in patients who have normal femoral pulse and who only underwent preoperative ultrasonography to rule out any hemodynamically significant lesion in the aortoiliac segment. Thus, it allows a selective arteriography to be performed in the affected lower extremity, providing a faster, safer and more cost-effective preoperative evaluation pt_BR
dc.language.iso other pt_BR
dc.subject Ultra-sonografia Doppler pt_BR
dc.subject Arteriografia pt_BR
dc.subject Revascularização pt_BR
dc.title Avaliação do eco-Doppler na predição da necessidade de arteriografia do território aorto-ilíaco em pacientes submetidos a revascularização arterial infra-inguinal pt_BR
dc.title.alternative Evaluation of the accuracy of Doppler ultrasonography to rule out the need for aortoiliac arteriography before infrainguinal arterial reconstruction pt_BR
dc.type Article pt_BR


Files in this item

Files Size Format View
ARTIGO_avaliaçãoecodoppler.PDF 402.1Kb PDF View/Open

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account