Comparação de percentuais de gordura corporal, utilizando impedância bioelétrica e a equação de Deurenberg

DSpace/Manakin Repository

Comparação de percentuais de gordura corporal, utilizando impedância bioelétrica e a equação de Deurenberg

Show simple item record

dc.contributor.author Alonso, Katia Cristina
dc.contributor.author Sautchuk, Francieli Guimarães
dc.contributor.author Malfatti, Carlos Ricardo Maneck
dc.contributor.author Artoni, Roberto Ferreira
dc.date.accessioned 2010-10-06T16:39:49Z
dc.date.available 2010-10-06T16:39:49Z
dc.date.issued 2009-01
dc.identifier.citation ALONSO, K. C. et al. Comparison of percentage of body fat, using eletric bioimpedance and the equation of Deurenberg. Cinergis, Santa Cruz do Sul, v. 10, n. 1, p. 29-34, jan./jun, 2009. pt_BR
dc.identifier.issn 1519-2512
dc.identifier.uri http://ri.uepg.br:8080/riuepg//handle/123456789/281
dc.description.abstract Com o crescimento da população obesa e com sobrepeso, o IMC (Índice de Massa Corporal) passou a ser uma análise amplamente empregada para resultados e classificações de composição corporal dada a simplicidade e exeqüibilidade do método. Erros inerentes ao IMC fomentam a utilização de outras ferramentas para a tomada de parâmetros corporais de relevância para a clínica assim como a porcentagem de gordura corporal. No pressente estudo realizamos uma comparação de reprodutibilidade dos resultados obtidos para o percentual de gordura corporal pelo método de impedância bioelétrica e pelo IMC corrigido pela Equação de Deurenberg. Os testes foram aplicados em 25 indivíduos (5 homens e 20 mulheres) com idade entre 17 a 75 anos. Os resultados obtidos apontam uma excelente correspondência e reprodutibilidade entre os métodos utilizados (r = 0,906). Estes dados iniciais sugerem a possibilidade de utilização destes índices para o diagnóstico de gordura corporal em percentagem, com a possibilidade de aplicação clínica. pt_BR
dc.description.abstract With the growth of the population obese or overweight, BMI (Body Mass Index) has become a widely applied to analysis results and ratings of body composition because of the simplicity and feasibility of the method. Errors associated with BMI increase the use of other tools for making body parameters of relevance to the clinic as well as the percentage of body fat. In the study we realized a comparison of reproducibility of results obtained for the percentage of body fat by the method of bioelectrical impedance and BMI corrected by Deurenberg equation. The tests were applied in 25 subjects (5 men and 20 women) aged 17 to 75 years. The results show an excellent correlation and reproducibility between the methods (r = 0.906). These initial data suggest the possible use of these indices for the diagnostic of body fat percentage, with the possibility of clinical application. pt_BR
dc.language.iso other pt_BR
dc.subject Indice de massa corporal pt_BR
dc.subject Obesidade pt_BR
dc.subject Biometria pt_BR
dc.title Comparação de percentuais de gordura corporal, utilizando impedância bioelétrica e a equação de Deurenberg pt_BR
dc.title.alternative Comparison of percentage of body fat, using eletric bioimpedance and the equation of Deurenberg pt_BR


Files in this item

Files Size Format View
ARTIGO_ComparaçãoPercentuaisGordura.pdf 97.27Kb PDF View/Open

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account