Aparelhos fotopolimerizadores: elevação de temperatura produzida por meio da dentina e durante a polimerização da resina composta

DSpace/Manakin Repository

Aparelhos fotopolimerizadores: elevação de temperatura produzida por meio da dentina e durante a polimerização da resina composta

Show simple item record

dc.contributor.author Godoy, Eloisa de Paula
dc.contributor.author Pereira, Stella Kossatz
dc.contributor.author Carvalho, Benjamim de Melo
dc.contributor.author Martins, Gislaine Cristine
dc.contributor.author Franco, Ana Paula Gebert de Oliveira
dc.date.accessioned 2010-09-03T14:43:15Z
dc.date.available 2010-09-03T14:43:15Z
dc.date.issued 2007-01
dc.identifier.citation GODOI, E. P. et. al. Aparelhos fotopolimerizadores: elevação de temperatura produzida por meio da dentina e durante a polimerização da resina composta. Rev. Clín. Pesq. Odontol., Curitiba, v.3, n.1, p.11-20, jan./abr. 2007. pt_BR
dc.identifier.uri http://ri.uepg.br:8080/riuepg//handle/123456789/120
dc.description.abstract OBJETIVO: Avaliar a elevação de temperatura de um fotopolimerizador de lâmpada halógena Optilux 401 (Demetron) e três LEDs: LEDemetron I (Kerr), Bluephase (Ivoclar Vivadent) e Elipar Freelight (3M ESPE). METODOLOGIA: Posicionando-se um termopar tipo-K sob um disco de dentina de 0,5 mm de espessura, verificou-se a elevação de temperatura produzida pelos aparelhos durante a fotopolimerização do sistema adesivo Scothbond™Multi-Purpose (3M ESPE) e de um incremento de 2 mm de espessura da resina composta Filtek™Z350 (3M ESPE), fotopolimerizados por 20 e 40segundos, respectivamente. RESULTADOS E CONCLUSÕES: A ANOVA e pós-teste de Bonferroni (5% de significância) mostrou que o LED Bluephase produziu os maiores valores de elevação de temperatura durante a polimerização do sistema adesivo (17,6ºC), sendo estatisticamente similar ao Optilux 401 (16ºC). O menor valor foi registrado para o Elipar Freelight com 7,2ºC no sistema adesivo e 3,1ºC na resina composta. A maior elevação de temperatura foi durante a fotopolimerização da resina composta (6,2ºC) com o Optilux 401. A elevação de temperatura registrada no sistema adesivo foi estatisticamente maior que a da resina composta (p<0,001). O Elipar Freelight registrou o menor valor de elevação de temperatura quando comparado aos demais aparelhos. pt_BR
dc.description.abstract OBJECTIVES: The objectives of this work was to study the temperature increase induced by a light-cured unit halogen Optilux 401 (Demetron) andd three LED light-curing units: LEDDemetron I, Bluephase and Elipar Freelight. METHOD: The temperature increase was recorded with a type-K thermopar, positioned under a 0.5 mm thick dentin disk during polymerization of the adhesive system AdperTMScothbond Multipurpose and in increments of 2 mm thickness of composite resin FiltekTMZ350, polymerized for 20 and 40 sec respectively. The data were submitted to ANOVA 1 way and Bonferroni post-test (5% significance). RESULTS and CONCLUSION: The LED light-curing Bluephase produced higher temperature increase during the polymerization of the adhesive system (17,6°C) being statistically same to the light-curing unit halogen Optilux 401 (16°C). The less temperature increase was recorded during polymerization adhesive system (7,2°C) for Elipar Freelight and 3,1°C in the composite resin. The higher temperature increase recorded during the polymerization of the composite resin reached 6,2°C for Optilux 401. The temperature increase recorded in the adhesive system was statistically higher than recorded during the polymerization of the composite resin (p < 0,001). The Elipar Freelight with less irradiance recorded the less temperature increase, where compared with other light-curing units selected. pt_BR
dc.language.iso other pt_BR
dc.subject Adesivos dentinários pt_BR
dc.subject Resinas compostas pt_BR
dc.subject Aparelhos fotopolimerizadores pt_BR
dc.title Aparelhos fotopolimerizadores: elevação de temperatura produzida por meio da dentina e durante a polimerização da resina composta pt_BR
dc.title.alternative Light-curing units: temperature rise induced through dentin and during pt_BR
dc.type Article pt_BR